An analytical study on early kick detection and well control considerations for casing while drilling technology
-
Abstract
Casing while drilling (CwD) technology is designed to reduce drilling time and expenses by improving the wellbore stability, fracture gradient, and formation damage while reducing the exposure time. However, for the purpose well control, the wellbore geometry and volumes differ from those obtained via a conventional drilling technique, thereby requiring a different approach. This study discusses well control principles for CwD operations. It presents a simplified method for evaluating the maximum kick tolerance and allowable well shut-in time for both conventional and CwD techniques using a mathematical model. Preliminary results revealed that the use of CwD leads to an annulus pressure loss three times higher than that observed in the conventional drilling. In addition, the kick tolerance is reduced by 50% and the maximum allowable well shut-in time is reduced by 65%, making an early kick detection system necessary.
-
-