Catalytic adsorptive stripping determination of trace chromium based on the bismuth/MWCNTs modified electrode

Cite this:
https://doi.org/10.3969/j.issn.0253-2778.2014.08.002
More Information
  • Author Bio:

    ZHAO Qiping, female, born in 1989, Master. Research field:Electroanalytical chemistry. E-mail:qpzhao@mail.ustc.edu.cn

  • Corresponding author: WU Shouguo
  • Received Date: 14 May 2014
  • Rev Recd Date: 03 June 2014
  • Publish Date: 31 August 2014
  • A sensitive Bi/MWCNTs (multi-walled carbon nanotubes) composite film modified electrode was fabricated by two-step electrodeposition. First, the MWCNTs were electrodeposited instead of dropping coated on the glass carbon electrode(GCE), and the bismuth film was then deposited on the MWCNTs/GCE. A protocol used for the determination of total chromium and hexavalent chromium in water by square wave cathodic adsorptive voltammetry in the presence of cupferron (N-nitroso-N-phenylhydroxylamine ammonium salt) was proposed. In the presence of cupferron, Cr(Ⅲ) can form the complex with cupferron and be accumulated on the surface of the modified electrode by adsorption at a potential of -035 V, and then is reduced with the cathodic scan from -035 V to -110 V. An accumulation time of 2 min results in a detection limit of 005 μg/L Cr(Ⅵ) and a relative standard deviation of 52% (n=75) for 10 μg/L. Application to river water samples is demonstrated. The total chromium can be directly determined by standard addition of Cr(Ⅲ) or Cr(Ⅵ); the Cr(Ⅵ) can be separated with Cr(Ⅲ) by using an anion trapping column and then determined by standard addition of Cr(Ⅵ). The results are consistent with those detected by ICP-MS (inductive coupled plasma mass spectrometry). The attractive behavior of the new “mercury-free” chromium sensor holds great promise for on-site environmental and industrial monitoring of chromium.
    A sensitive Bi/MWCNTs (multi-walled carbon nanotubes) composite film modified electrode was fabricated by two-step electrodeposition. First, the MWCNTs were electrodeposited instead of dropping coated on the glass carbon electrode(GCE), and the bismuth film was then deposited on the MWCNTs/GCE. A protocol used for the determination of total chromium and hexavalent chromium in water by square wave cathodic adsorptive voltammetry in the presence of cupferron (N-nitroso-N-phenylhydroxylamine ammonium salt) was proposed. In the presence of cupferron, Cr(Ⅲ) can form the complex with cupferron and be accumulated on the surface of the modified electrode by adsorption at a potential of -035 V, and then is reduced with the cathodic scan from -035 V to -110 V. An accumulation time of 2 min results in a detection limit of 005 μg/L Cr(Ⅵ) and a relative standard deviation of 52% (n=75) for 10 μg/L. Application to river water samples is demonstrated. The total chromium can be directly determined by standard addition of Cr(Ⅲ) or Cr(Ⅵ); the Cr(Ⅵ) can be separated with Cr(Ⅲ) by using an anion trapping column and then determined by standard addition of Cr(Ⅵ). The results are consistent with those detected by ICP-MS (inductive coupled plasma mass spectrometry). The attractive behavior of the new “mercury-free” chromium sensor holds great promise for on-site environmental and industrial monitoring of chromium.
  • loading
  • 加载中

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return